XPS- Design Factors for Extruded Polystyrene Roofing Insulation

Extruded polystyrene insulation provides specific properties that differentiate that from other types of foam plastic insulation and therefore make it ideal for several roof designs.

co extruder

Extruded polystyrene insulation has exceptional properties that differentiate it from other styles of foam plastic insulation and therefore make it ideal for several roof designs.

Sometimes considered « the other roof insulation,  » XPS is specified when higher compressive strength generally, higher water resistance and higher thermal resistance found in the presence of water are needed. Those qualities make XPS the most well-liked choice in green-planted roofing systems, protected or inverted membrane plaza deck systems, white or « cool » single-ply roofing and metal roofing systems.

When considering sustainable, sturdy roofing designs it’s vital that you start with how water resistant an insulation material is. Extruded polystyrene is manufactured to comply with ASTM C578, « Standard Specification for Rigid, Cellular Polystyrene Thermal Insulation. » ASTM C578 is also the principal reference standard used for specifying polystyrene insulations, meaning it defines physical houses for both extruded polystyrene and expanded polystyrene.

You can find fundamental differences between the properties of XPS and EPS, which are critical to understanding why XPS is fantastic for applications that require high resistance to moisture intrusion. Water absorption by total immersion for XPS is outlined at 0.3 percent optimum by volume, compared to 2.0 to 4.0 percent for EPS, based on its density. How much drinking water absorption is usually a function of the composition of every material.

The hydrophobic and homogeneous closed-cell structure of XPS makes it resistant to water intrusion. This is a significant contrast in comparison with the make-up of an EPS plank. Although EPS beads happen to be hydrophobic and closed-cell, the beads are also surrounded by voids. These voids are in charge of the bigger water absorption volume within the finished EPS board. The blowing agent found in EPS is definitely quickly changed by air flow and paired together with these voids the effect is an EPS insulation product with lower thermal level of resistance characteristics when compared to XPS. As EPS density raises, these voids decrease, yielding less prospect of water absorption and a rise in thermal resistance.

Polyisocyanurate rigid insulation is manufactured to comply with ASTM C1289, « Common Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Panel. » Polyiso chemistry includes monomers that are hydrophilic. The cell framework tends to be irregular in proportions and shape and less defined compared to XPS. Because of these dissimilarities, polyiso has higher water absorption than XPS – one to two 2 percent by volume, with respect to the classification and type, which comes even close to XPS at 0.3 percent. Also, it is important to note that the polyiso common requires a test technique that measures drinking water absorption following a two-hour immersion in drinking water and 10-minute drain time, versus the XPS check method that runs on the 24 hour immersion and requires no drain period.

Truly « green » roofs are becoming more common, in dense cities particularly. There are two simple types of green roofs – extensive and intensive. Extensive and intensive roofs differ in expense, depth of growing mass media and the choice of plants.

Extensive roof cover media varies in depth between 2 inches and 6 inches with a weight increase of between 16 pounds per square foot to 35 pounds per square foot when saturated. Intensive green roof cover media varies comprehensive between 8 inches and 24 in . with a weight increase of between 60 pounds per square ft . to 200 pounds per square ft . when saturated. Green roofs provide a thermal mass impact, which in turn saves energy and provides reduced heating and cooling costs. Other rewards include reduced water runoff, expanded useful lifestyle of the roof, and added beauty and useable space.

Foremost at sustainability objectives of a green roof are to retain water and reduce storm water discharge, and to conserve energy through the cooling and shading properties of soil and plantings that may substantially reduce heat flow into a building, lowering the strain placed on air-con equipment thus.

The highly water-resistant characteristic of XPS roof insulation actually « enables » green roof construction. Green roofs are constructed in an inverted configuration typically, and therefore the insulation is on top of the waterproofing membrane instead of under it as in classic roof systems. An eternity of contact with retained water helps it be crucial that the insulation applied retains R-worth, possesses compressive strength and other critical houses while exposed to water. For that good reason, XPS is almost exclusively used to insulate backyard roofs. When specifying, one can pick from XPS ASTM C578 Type VI, V or vii to most effective fit the design requirements of this roof.

XPS is durable also, rendering it reusable when removal and reinstallation are necessary for repairs. For many of these characteristics, XPS is the only insulation recommended for back garden roof systems in the NRCA Green Roof Systems Manual, 2007 Edition.

LEED defines « fascinating roofs » as roofing floors or systems that reduce temperature islands. A heating island is a designed area which has a significant temperature difference compared to adjacent undeveloped areas. The LEED-NC 2.2 cool roofing definition includes roofs that are either green/vegetated, as already discussed, or roof floors with a Solar Reflectance Index equal to or higher than 78.

Common cool roof single-ply membranes include thermoplastic olefin (TPO) and polyvinyl chloride. Both materials can be found in white readily, which makes them an extremely affordable option for employ with XPS roofing insulation in both unique and reroof applications.

XPS is frequently used under all types and colors of single-ply roofing membranes but it must be protected from solar warmth by a cover plank when used under non-white membranes in new building and reroofing with total tear-off. In those applications, a cover board must be placed on the XPS to separate it from the membrane. Dark-membrane-to-XPS interface temperature ranges can methodology 190 to 200 degrees Fahrenheit, which exceeds the recommended service temperature of 165 degrees Fahrenheit for XPS. So a cover panel is needed to independent the dark membrane from XPS. Common cover boards employed under dark membranes involve high-density solid wood fiber or water-resistant gypsum board.

Mechanically attached TPO and PVC membranes require simply an inexpensive slip-sheet separation from XPS. The slip-sheet is needed to achieve a Category A (ASTM E108) fire score with TPO, or even to chemically different PVC from the XPS (see Figure 5).

These systems can also be installed « immediate to deck » lacking any underlying gypsum board thermal barrier layer. Because the mid-1990s, XPS roofing insulation systems have been outlined at Underwriters Laboratories (UL) for direct-to-steel roofing deck application (check out UL Roof Deck Development numbers 440 and 457). The listed roof deck systems were analyzed for flame spread under the steel roof deck (not hourly rated) in accordance with UL Common 1256 as referenced in Section 2603.4.1.5 of the 2006 International Building Code.

XPS roofing insulation types X, IV and V are commonly used in combination with mechanically attached awesome white roofing membranes and a straightforward slip-sheet. XPS and the white membrane, mounted to the steel roof deck straight, combine to produce a sustainable roofing system highly. Great SRI is achieved, while material installation and use labor is minimized as cover boards and underlying thermal barrier layers are eliminated.

Beyond those immediate benefits, life-routine price is minimized with XPS which has the water resistance to endure the inevitable roof structure leaks that happen as roofs age. XPS will maintain its properties in the current presence of water in the event that leaks develop over the lifestyle of the building, as well making it reusable after leaks are repaired. Water resistant insulation means the roofing system will retain its R-value and energy preservation power even when subjected to moisture from leakages. Water resistance does mean retention of compressive power and retention of tensile load on roof system fasteners, holding the roofing secure until fixes are accomplished. Reusable insulation means reduced tear-off materials taken up to landfills.

Metal roofing systems rely on XPS insulation to supply high compressive strength for a well balanced substrate to properly chair the base of clips used to add the roof, and for water resistance to provide a second water barrier under the roofing panels.

ASTM C578 Type IV XPS insulation has excellent compressive strength for mounting standing-seam steel roof panels. Compressive resistance establishes first fastener minimizes and load long-term creep to maintain fastener load retention as time passes. Yet the XPS surface is adaptable enough to allow the clips to seat properly in the surface of the insulation, and with no adhered facing material you don’t have to trim around the clip for proper seating, saving labor and cost. A recent study of an XPS insulated metal roof, after 10 years in service under metallic roofing clips revealed clip stability and continuing fastener load retention.

The National Roofing Contractors Association recommends a layer of asphalt-saturated felt between the insulation layer and standing seam metal roof to supply a drainage plane in buildings with high prospect of condensation. The NRCA Waterproofing and Roofing Manual recommends using a vapor retarder with a permeation rating of 0.5 perms or less using climate zones. When installed with sealed joints, highly water-resistant XPS insulation eliminates the need for these additional layers.

The water resistance of XPS also enables more flexible job staging. It isn’t uncommon for various elements of the roofing assembly to possess delayed delivery. XPS insulation can be installed continuously and sealed accompanied by the metal roof because the schedule permits. Manufacturers of XPS do not require that the insulation panel be covered or safeguarded since it is installed because of its resistance to work site water absorption. It’s quite common practice for XPS insulation, with sealed joints, to serve as a temporary roof when delivery of the standing-seam roof is delayed. After 30 to 60 days, according to the strength of UV exposure, XPS insulation board can start to fade in color. And while exposed XPS produces a good temporary water-resistant covering, it isn’t intended to remain uncovered for extended periods of time.

Standing seam steel roofing systems which are installed more than XPS insulation can perform a Class A rating directly. Consult UL listings for whole details and specific product listings. XPS insulation can be UL Fire Classified with metallic roof covering systems for installation immediate to structural steel roof deck without an underlying thermal barrier. XPS insulation is not recommended for use straight under black metallic or copper roofs because of potential high temperature absorption generating temperatures in excess of the maximum XPS service temperature. When specifying black steel or copper roof panels, the very least thickness of 1/4-inch moisture resistant gypsum board is preferred between the XPS insulation and metal roof.

ASTM E119 is the test technique that determines the timed structural fire level of resistance of a roofing assembly. Steel roofing deck assemblies insulated with any sort of foam plastic insulation generally require some type of fire resistant level to achieve an hourly ranking. When XPS insulation is used in an hourly ranked assembly, a level of 5/8-in . type X gypsum plank should be installed on top of the steel deck relative to the particular UL assembly specification. Alternate safeguard layers in lieu of, or furthermore to, gypsum board can include sprayed fibrous or cementitious coatings applied to the bottom side of the steel deck. Concrete roofing decks are inherently more fire resistant than metal and have a different set of criteria for score. Watch particular assembly listings for the proper execution and amount of safeguards required.